ORIGINAL ARTICLE
Year : 2023 | Volume
: 38 | Issue : 1 | Page : 8--15
99m-Tc MDP bone scan image enhancement using pipeline application of dynamic stochastic resonance algorithm and block-matching 3D filter
Anil Kumar Pandey1, Gagandeep Kaur1, Jagrati Chaudhary1, Angel Hemrom1, Jasim Jaleel1, Param Dev Sharma2, Chetan Patel1, Rakesh Kumar1 1 Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, India 2 Department of Computer Science, SGTB Khalsa College, University of Delhi, New Delhi, India
Correspondence Address:
Dr. Anil Kumar Pandey Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi - 110 029 India
Introduction: In this pilot study, we have proposed and evaluated pipelined application of the dynamic stochastic resonance (DSR) algorithm and block-matching 3D (BM3D) filter for the enhancement of nuclear medicine images. The enhanced images out of the pipeline were compared with the corresponding enhanced images obtained using individual applications of DSR and BM3D algorithm. Materials and Methods: Twenty 99m-Tc MDP bone scan images acquired on SymbiaT6 SPECT/CT gamma camera system fitted with low-energy high-resolution collimators were exported in DICOM format to a personal computer and converted into PNG format. These PNG images were processed using the proposed algorithm in MATLAB. Two nuclear medicine physicians visually compared each input and its corresponding three enhanced images to select the best-enhanced image. The image quality metrics (Brightness, Global Contrast Factor (GCF), Contrast per pixel (CPP), and Blur) were used to assess the image quality objectively. The Wilcoxon signed test was applied to find a statistically significant difference in Brightness, GCF, CPP, and Blur of enhanced and its input images at a level of significance. Results: Images enhanced using the pipelined application of SR and BM3D were selected as the best images by both nuclear medicine physicians. Based on Brightness, Global Contrast Factor (GCF), CPP, and Blur, the image quality of our proposed pipeline was significantly better than enhanced images obtained using individual applications of DSR and BM3D algorithm. The proposed method was found to be very successful in enhancing details in the low count region of input images. The enhanced images were bright, smooth, and had better target-to-background ratio compared to input images. Conclusion: The pipelined application of DSR and BM3D algorithm produced enhancement in nuclear medicine images having following characteristics: bright, smooth, better target-to-background ratio, and improved visibility of details in the low count regions of the input image, as compared to individual enhancements by application of DSR or BM3D algorithm.
How to cite this article:
Pandey AK, Kaur G, Chaudhary J, Hemrom A, Jaleel J, Sharma PD, Patel C, Kumar R. 99m-Tc MDP bone scan image enhancement using pipeline application of dynamic stochastic resonance algorithm and block-matching 3D filter.Indian J Nucl Med 2023;38:8-15
|
How to cite this URL:
Pandey AK, Kaur G, Chaudhary J, Hemrom A, Jaleel J, Sharma PD, Patel C, Kumar R. 99m-Tc MDP bone scan image enhancement using pipeline application of dynamic stochastic resonance algorithm and block-matching 3D filter. Indian J Nucl Med [serial online] 2023 [cited 2023 Mar 26 ];38:8-15
Available from: https://www.ijnm.in/article.asp?issn=0972-3919;year=2023;volume=38;issue=1;spage=8;epage=15;aulast=Pandey;type=0 |
|